This standard is issued under the fixed designation C; the number Conversion and rounding given in Standard IEEE/ASTM SI. The intention of this article is to clarify the specifications listed in ASTM C, Standard Specification for Mixing Rooms, Moist Cabinets, Moist. ASTM C Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage. Tanks Used in the Testing of Hydraulic Cements and Concretes.

Author: Kelabar Vudole
Country: Suriname
Language: English (Spanish)
Genre: Life
Published (Last): 21 September 2005
Pages: 338
PDF File Size: 3.13 Mb
ePub File Size: 3.80 Mb
ISBN: 579-3-50184-297-3
Downloads: 3251
Price: Free* [*Free Regsitration Required]
Uploader: Vilkis

Water storage tanks shall be constructed of non-corroding materials with provisions for automatic control of water temperature. In order to maintain an extremely humid environment, you must have a good water supply and humidifying equipment, and the temperature must be maintained at Trying to cut corners on curing can produce erroneous test results.

Air in moist cabinet or moist room shall be saturated with moisture in order to provide specified storage conditions and air temperature shall be controlled with provisions made for heating, cooling, or both.

To help reduce exposed surface area, try covering the tanks with large pieces of Styrofoam insulation. The best way to make sure that you have a well-circulated, temperature-controlled facility that meets all of the requirements is to take the time and money to get it right the first time. If you have more than one tank, you have two options for configuration.

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. There is no set lbs of calcium hydroxide per gallon of water. ICS Number Code Maintaining two sets of working spray nozzles will be less time consuming than continuously repairing dripping nozzles, or suffering the consequences of improperly cured materials.

Historical Version s – view previous versions of standard. Dry conditions, low temperatures, and abundant fresh water leaching can all lead to low strength specimens. Importance The importance of having a properly functioning curing facility cannot be overstated. How much calcium hydroxide do you use per gallon of water for a cure tank?

  7808CT DATASHEET PDF

Some of the most common errors include: Moist rooms can be expensive to build and maintain, but they also hold more specimens, which are easier to organize and locate when placed on shelves. If you decide to go this route, you will need to have at least one calibrated chart recorder or digital recorder per tank see Figure 1. Both curing tanks and moist rooms have their benefits and drawbacks.

Learn how to be an AASHTO lab 24/7

No other units of measurement are included in this standard. Curing facilities, be they tanks or rooms, require lots of documentation. Take extra care to ensure that the flow between the tanks is even. Astj consider all the man hours lost to constant maintenance and quick-fixes, not to mention having to spend time writing corrective action reports for your AASHTO re: In both cases, extreme care must be taken to prevent water from dripping onto the stored specimens, since lime can leach out and lower the strength.

While it is nice to be able to have all of the temperature records on a computer, CCRL inspectors astn that laboratories using these data loggers often forget to download and evaluate the data.

The Cure for The Cure: A Guide to ASTM C and Your Curing Facilities

From Table 1 it looks like it. The first option is to equip each tank with a temperature recorder that is monitored weekly.

Accidentally draining and overflowing a tank can occur if there is an equipment malfunction. Curing rooms range in size, and it is recommended that labs install shelving in a configuration convenient to the size and shape of the room.

If the calcium hydroxide is disappearing when stirred, the water is not saturated. Whichever option you choose, you must be capable of heating or cooling the system, regardless of your geography, even if the laboratory is located in a region with a fairly consistent climate.

  GLENN WELSCH PRESUPUESTO PDF

Most labs that choose this method use a fish pond circulator. Can Portland cement grout cubes be cured in a water tank instead of curing cabinet?

You’ve already submitted a review for this item. Unless you are a new lab, thinking of rebuilding, or moving to a new building, you probably already have a curing facility set up.

Thank you for the comment! Tanks near drafty bay doors will also wreak havoc on any kind of temperature control you think you have. Subscribe to new comments. High temperatures can lead to falsely high strength.

Since there seems to be a lot of confusion and misunderstanding regarding curing facilities and their requirements, I decided to write an article about them. Depending on c151 type of material you are working with, you should refer to the applicable specification or standard to determine whether you need to maintain tanks or a curing room, or even a tank within a curing room.

It is best to have them inside and against an interior wall. Login to be able to comment. Fill the tanks with water that has been saturated with lime calcium hydroxide, a.

ASTM C Standard

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Have you ever wondered which option your competitor is using? It is important to choose temperature charts that are c5111 read and do not have a scale so small that the pen or marker line width exceeds the scale lines.