ASTM D6760 PDF

This standard is issued under the fixed designation D; the number 1 This test method is under the jurisdiction of ASTM Committee D18 on Soil and. All the Controls products ASTM D standard. Enter now!. ASTM D (Ultrasonic Crosshole Testing).pdf – Download as PDF File .pdf ), Text File .txt) or read online.

Author: Arashijora Zolojar
Country: Cambodia
Language: English (Spanish)
Genre: Travel
Published (Last): 17 October 2006
Pages: 324
PDF File Size: 17.16 Mb
ePub File Size: 7.49 Mb
ISBN: 793-6-49325-629-9
Downloads: 34908
Price: Free* [*Free Regsitration Required]
Uploader: Kimuro

Active view current version of standard D676 Standard: Your basket is empty. This method is most applicable when performed in tubes that are installed during construction. Testing should therefore be performed as soon as practical in order to avoid debonding issues.

Click to learn more. You may experience issues viewing this site in Internet Explorer 9, 10 or We use cookies to make our website easier to use and to better understand your needs. No other units of measurement are included in this standard. Reliable results depend on many factors; Practice D provides a means of evaluating some aetm those factors. Find Similar Items This product falls into the following categories.

How one applies the results obtained using this standard is beyond its scope. Referenced Documents purchase separately The astn listed below are referenced within the subject standard but are not provided as part of the standard. Please download Chrome or Firefox or view our browser tips.

This test can assess to the integrity of the concrete mainly in the area bounded by the access ducts, which means typically inside the reinforcement cage. Take the smart route to manage medical device compliance. The method does not give the exact type of flaw for example, inclusion, honeycombing, lack of cement particles, etc. How one applies the results obtained using this standard is beyond its scope.

This website is best viewed with browser version of up to Microsoft Internet Explorer 8 or Firefox 3. These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard. Worldwide Standards We can source any standard from anywhere in the world. The data are used to confirm adequate concrete quality or identify zones of poor quality.

  COURSE 6425C PDF

Search all products by. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency requiring the test smay provide additional requirements and procedures as needed to satisfy the objectives of a particular test program. Agencies that meet the criteria of Practice D are generally considered capable of competent and objective testing and inspection.

The method does not give the exact type of defect for example, inclusion, honeycombing, lack of cement particles, etc.

ASTM D6760 – 16

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Users of this standard are cautioned that compliance with Practice D does not in itself assure reliable results.

This method is most applicable when performed in tubes that are installed during d6670.

Learn more about the cookies we use and how to change your settings. Active view current version of standard. No other units of measurement are included in this standard.

ASTM D, Test equipment Controls

The faster, easier way to work with standards. Link to Asstm This link will always route to the current Active version of the standard.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This method can also be extended to diaphragm walls, barrettes, dams etc.

  EXTRON DVI DA2 PDF

The method is limited primarily to testing the concrete between the access ducts and thus gives little information about the concrete outside the reinforcement cage to which the access ducts are attached when the tubes are attached to the inside of the reinforcement cage.

Historical Version s – view previous d66760 of standard. The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used.

These notes and footnotes excluding those in tables and figures shall not be considered as requirements of the standard. Link to Active This link will always route to the current Active version of the standard. You may find similar items within these categories by selecting from the choices below:.

Since the generated waves travel through the concrete around the zstm duct, unless a flaw is massive enough and very near to the access duct it may not be detected by this method. Accept and continue Learn more about the cookies we use and how to change e6760 settings. This method can also be extended to diaphragm walls, barrettes, dams etc. Plans, specifications, provisions, or combinations thereof prepared by a qualified engineer, and approved by the agency axtm the test smay provide additional requirements and procedures aatm needed to satisfy the objectives of a particular test program.

Barrette, Bored pile, Crosshole sonic logging, Crosshole testing, Drilled shaft, Integrity test, Single hole ultrasonic testing, Ultrasonic logging, Ultrasonic testing.

If defects are detected, then further investigations should be made by excavation or coring the concrete as appropriate, or by other testing such as Test Method DD or Dand measures taken to remediate the structure if a defect is confirmed.